Method for attaching Primer fitting

Anything having to do with an engine that powers any Aeronca aircraft
Post Reply
jkvincent
Posts: 476
Joined: Wed Jun 21, 2006 22:34
Location: Houston, Tx
Contact:

Method for attaching Primer fitting

Post by jkvincent »

My Primer line has been rubbing against something and it needs to be changed out, but I noticed the Cone fitting
(AN 800-2) at the end is semi-permanently attached to the line.
How would I remove and re-attach the fitting * to new aluminum or copper line?
Looks like it might be soldered or JB Weld?
thanks, Jim

Image
User avatar
joea
Site Admin
Posts: 5993
Joined: Thu Nov 11, 2004 13:01
Location: Phoenix Arizona
Contact:

Post by joea »

Jim,

This part can either be soldered to the metal tube or some are compression style fittings.

Can you get the tubing off to the point where you can take it somewhere to get new tubing? Most of this is plain 1/8th copper tubing and should be easily available.

Joe
jkvincent
Posts: 476
Joined: Wed Jun 21, 2006 22:34
Location: Houston, Tx
Contact:

Post by jkvincent »

Joe,
Yep, I have the old line off, and no problem on new tubing, I have new alum tube ready to go.
Ideally, can I just heat up the old tubing/Cone to melt the solder and then solder that Cone onto the new Alum tubing?
I thought about just a regular Compression Ring but this Cone appears to have a larger diameter than a 1/8" compression ring.
If I use AN fittings, what fittings would I need to attach to the Jet Primer?
The Jet Primer appears to have a (normal) 37 degree female receptacle, which makes me believe AN fittings won't work here.
Jim
User avatar
joea
Site Admin
Posts: 5993
Joined: Thu Nov 11, 2004 13:01
Location: Phoenix Arizona
Contact:

Post by joea »

Jim,

A question. Why are you using aluminum tubing? Is the original copper or aluminum? Have never seen aluminum used for primer in the firewall forward area.

Not sure on the fittings themself but remember that much of this is 1930's tech and many of the parts were from a tractor store.

Joe
Paul Agaliotis
Posts: 2589
Joined: Wed Dec 08, 2004 18:49
Location: San Martin, California
Contact:

Post by Paul Agaliotis »

Jim,
If you use the aluminum line you need to have the correct flux for soldering steel to the aluminum.
Cessna uses a lot of these fittings silver soldered to the steel primer lines.
If you plan to change to a compression style fitting the primer nozzle will need to be replaced.
Paul
Mailing Adress : Paul Agaliotis 2060 E. San Martin, San Martin,Calif. 95046
User avatar
joea
Site Admin
Posts: 5993
Joined: Thu Nov 11, 2004 13:01
Location: Phoenix Arizona
Contact:

Post by joea »

Paul,

Glad you chimed in here. Any reason to use aluminum?

Have always been concerned about vibration and thus used copper from firewall forward for any hard lines carrying fluids. Guess if Cessna uses it then its ok but...

Joe
Paul Agaliotis
Posts: 2589
Joined: Wed Dec 08, 2004 18:49
Location: San Martin, California
Contact:

Post by Paul Agaliotis »

I have never used aluminum and choose the annealed copper or steel for primer lines.
I like the compression fittings for ease of manufacture and repair. I will fix the line using the AN800 only when the primer and nozzle is machined for this style fitting, to save the replacement costs.
Paul
Mailing Adress : Paul Agaliotis 2060 E. San Martin, San Martin,Calif. 95046
jkvincent
Posts: 476
Joined: Wed Jun 21, 2006 22:34
Location: Houston, Tx
Contact:

Post by jkvincent »

thanks guys, ...no particular reason for Alum., (I already had it at the hangar).
I'm headed out there in a couple of days with a small portable Butane bottle
and if I can cleanly separate the Cone from the (old) copper line,
then I'll stay with new copper.
Jim
Post Reply